Dermatitis : contact, atopic, occupational, drug · 2017
Read the original publication at the publisher’s page
| Studied in | People |
|---|---|
| Health topics | Contact allergy |
| Sunscreen chemicals | sulisobenzone |
Our transcription
When 4871 people with stubborn rashes were patch tested at 13 clinics across the United States and Canada in 2013 and 2014, two thirds of them, 66.8 percent, turned out to be allergic to at least one common chemical, and for 49.9 percent of the patients, contact allergy was the primary diagnosis behind their dermatitis. The North American Contact Dermatitis Group, a network of dermatologists, runs this census every two years with a screening tray of 70 allergens; this report is the 2013 to 2014 edition.
Patch testing is not a blood test and not a skin prick. Suspected allergens are taped to the back in small chambers, then read and graded by a dermatologist, who also judges from the patient's history and examination whether each reaction is genuinely relevant to the rash being investigated.
Nickel sulfate led the list again, positive in 20.1 percent of those tested, its highest level since the group began systematically reporting. The authors argue this should push North America toward the kind of limits the European Union places on nickel that leaches from items touching skin. Fragrance mix I followed at 11.9 percent. The newcomer was methylisothiazolinone, or MI, a preservative added to the tray for the first time this cycle: it debuted in third place at 10.9 percent. Neomycin, bacitracin, cobalt chloride, balsam of Peru, the hair dye chemical p-phenylenediamine, formaldehyde, and the preservative pair methylchloroisothiazolinone/methylisothiazolinone, or MCI/MI, filled out the top ten.
The MI result is the report's sharpest finding: the sensitivity epidemic previously documented in Europe is also occurring in North America, the authors conclude. MCI/MI was the only allergen tested in every cycle since 2001 whose rates rose significantly against both the previous cycle, with a risk ratio of 1.26, and the pooled twelve years before it, with a risk ratio of 2.08, roughly a doubling.
Of the seven newly added test preparations, four drew reactions in more than 2 percent of patients: formaldehyde at a 2 percent concentration, at 7.0 percent, diphenylguanidine at 3.8 percent, propylene glycol at full strength at 2.8 percent, and benzophenone-4, a sunscreen chemical, at 2.1 percent. Benzophenone-3, better known as oxybenzone, also sat on the tray and stayed rare at 0.6 percent.
More than a fifth of the patients, 21 percent, were allergic to something the 70-allergen tray does not carry, and 14.6 percent of those reactions were work related. The most common sources of these off-tray allergens were cosmetics and personal care products, then medications, then clothing and protective equipment. A commercial 36-allergen panel, the T.R.U.E. TEST, would hypothetically have detected only 66.0 to 75.9 percent of the reactions the full tray found.
The preservative churn of the consumer market shows in the trend data. Positive reactions to formaldehyde-releasing preservatives such as quaternium-15 fell 27 to 54 percent against the pooled 2001 to 2012 rates, and parabens fell too, though the authors note parabens remain among the safest preservatives from a contact allergy standpoint. What replaced them, MI above all, is what is climbing. Meanwhile reactions to hydroxyethyl methacrylate, or HEMA, an acrylic used in dental work and gel nails, rose significantly to 2.6 percent, in an industry the authors size at more than 8.5 billion US dollars across 129,000 American nail salons in 2015.
The authors flag their limits: these are referral patients, not a sample of the general population; the group's membership changed during the cycle, with two new clinics contributing 898 patients; and an allergen supplier change after the 2009 to 2010 cycle could shade the long-term comparisons.
The conclusion is about the test tray rather than any single chemical. Patch testing with allergens beyond a standard screening series, including personal products and workplace materials, the authors write, is necessary to fully evaluate contact dermatitis, at work and away from it.
Cited in
Related studies
- Case report: acute facial swelling in a recreational technical diver
- Patch test results in a Dutch paediatric population with suspected contact allergy: A retrospective cohort study
- Allergic contact dermatitis caused by benzophenone-4 in a printer
- Allergic contact dermatitis to personal care products: A focus on established and emerging allergens
- Benzophenone 4: an emerging allergen in cosmetics and toiletries?
